Hazardous area classification is an important part of managing explosion risk, but zoning alone does not demonstrate that risk is adequately controlled.
A robust hazardous area risk assessment needs to consider the wider requirements of Dangerous Substances and Explosive Atmospheres Regulations (DSEAR), alongside the protective functions that help prevent or mitigate credible accident scenarios.
DSEAR, Functional Safety and Zoning
Hazardous area zoning identifies where explosive atmospheres may occur and defines the requirements for equipment operating within them, but on its own does not ensure that the risk of an explosion is adequately controlled.
Functional safety complements zoning by ensuring that protective systems, such as gas detection, automated isolation, interlocks and venting/relief systems, operate reliably before or after a hazardous event occurs.
Functional safety requirements, including the required Safety Integrity Level (SIL), are derived from risk assessment (considering the likelihood and consequence of an event and reliability of each safeguard), rather than inferred from zone classification alone. By integrating all three disciplines, operations can justify their equipment selection, specify appropriate protective functions and demonstrate that the overall explosion risk is adequately controlled under DSEAR.
Where assessments can fall short
The cost of over-zoning
Although zoning is a principle important element in ATEX DSEAR assessment, there is a risk of inflating the cost if classification errors are made during the zoning process. A relevant example to highlight is the powder blender and the avoidance of flammable atmospheres.
A powder blending unit mixing metal powder used a nitrogen inerting system with oxygen monitoring. This was previously assigned a Zone 22 but has the potential for being a non-hazardous/negligible extent if the inerting is suitable, reliable and safe, such as ensuring oxygen levels (flammable atmospheres) are within the powder’s Maximum Permissible Oxygen Concentration (MPOC). Typically, two out of five variables should be present to ensure an inert atmosphere (flow, pressure, vacuum, time or oxygen analysis).
Assessing the level of integrity required for the inerting system can be complex, but should be considered by initially conducting a Layer of Protection Analysis (LOPA) study. This may then require a detailed Safety Integrity Level (SIL) determination assessment (functional safety) of the hazard scenario. It may be necessary to consider what the effect of a power failure would be.
If there is a reliable inerting system with monitoring and interlocks, the hazardous zone within the blending unit can be made less onerous from a Zone 22 to a non-hazardous/negligible extent internal zone. This is a clear example of how functional safety can align with area classification and DSEAR to reduce the cost of compliance.
Importance of an integrated assessment
The case illustrates why hazardous area classification should not be considered in isolation.
Effective risk management depends on understanding where explosive atmospheres may occur, controlling the conditions that can lead to their formation and ensuring that protective systems perform when demanded.
Bringing DSEAR, zoning and functional safety together can help operators reach decisions that are both technically justified and practical to implement.